Voltage drop
Quote:
Originally Posted by Masterlu
True dat! aka less of a voltage drop.
|
Here you go: (a couple of more posts on this thread and we can all take the Journeyman Electrician exam!!!)
120 Volt, Conductor size (AWG)
Single Phase, Max 3% Voltage Drop*
Length of Run
............25' 50' 100' 150' 200'
Copper 14 12 10 8 6 ...15 AMP**
Copper 12 12 8 6 4 ...20 AMP**
Copper 10 10 6 4 4 ...30 AMP**
https://www.cerrowire.com/products/r...e-drop-tables/
__________________
Main - Roon on Synology/Sonos Port/SoTM Neo endpoints; Chord Qutest, Bryston BP-17 cubed with phono option; EAT C-sharp with Ortofon Bronze MM, Bryston cubed Amplifier; Revel F126Be on custom Atocha stands; interconnects by WireWorld, furniture by Atocha Design 'Phones Audeze LCD-3, Bryston BHA-1; Office: Sonos/Roon; OPPO HA-1, Naim NAP100 and PSB Mini-C. Media Room:, Samsung QLED QN90 series, Sonos, OPPO 205, ATI N-core driving KEF LS-50's with REL subs; furniture by Glassisimo; Kids - U-turn for vinyl, Sonos Play5; Summer Shack - Sonos, vintage Pioneer, Dynaudio Special 40's.
Last edited by clpetersen; 07-15-2022 at 03:30 PM.
|