Steve.......Unless your two dedicated circuits have #10 AWG wire from the panel to each receptical I would not install 30 amp single-pole circuit breaks in place of the 20 amp circuit breakers. It could create a fire hazard and it is against the National Electric Code to do so.

With the 30 amp single pole circuit breakers installed, the correct size wire installed and 30 amp single phase outlets you will be in better shape for the breakers to handle the inrush current the amplifiers demand when energized. It is highly unlikely you will ever push the amplifiers with music to cause the Evo 900e's to require the 5000 watts (41.66 amps) at 120 volts so 30 amp single pole circuit breakers will serve you much better than your present arrangement. I suggest you contact a licensed electrician or electrical contractor to get the work done correctly and to code. Do it once, do it right.
__________________
Dan



STUDIO - McIntosh C1000C/P, MC2301 (2), MR88, Aurender N10, Esoteric K-01X, Shunyata Sigma spdif digital cable, Sonos Connect, PurePower 2000, Stillpoints, Furutech Flux 50, Michell Gyro SE, Michell HR Power Supply, SME 309, Ortofon Cadenza Black, Wireworld, Sonus faber Amati Anniversario
LIVING ROOM - McIntosh C2300, MC75 (2), MR85, Magnum Dynalab 205, Simaudio MOON Neo 260D-T, Schiit Audio Yggdrasil, Aurender N100H, Shunyata Sigma USB cable, Micro Seiki DD40, Ortofon Cadenza Blue, Nakamichi BX-300, Sony 60ES DAT, PS Audio P10, Furutech Flux 50, Sonos Connect, Stillpoints, Wireworld, Kimber, PMC EB1i, JL Audio f113
VINTAGE - McIntosh MA230, Tandberg 3011A tuner, Olive 04HD, Sony DTC-59ES DAT, McIntosh 4300V, JBL 4312A
Reply With Quote